Description

APC Galaxy 300 80KVA 3 Phase UPS G3HT80KHB2S 20MIN

APC Galaxy 300 80KVA 3 Phase UPS G3HT80KHB2S 20MIN from the leading APC dealer in Nairobi Kenya, buy online APC Galaxy 300 80KVA 3 Phase UPS G3HT80KHB2S 20MIN and have it delivered.

General
PROVIDED EQUIPMENT
CD with software
Dust filter
Installation guide
Network management card
User manual
BYPASS WIRING CONFIGURATION
5 wire (3P + N + E)
NUMBER OF POWER MODULE FREE SLOTS
0
NUMBER OF POWER MODULE FILLED SLOTS
0
REDUNDANT
No
UPS SIZE
WS
Physical
DEPTH
95 cm
HEIGHT
190 cm
MOUNTING PREFERENCE
No preference
NET WEIGHT
1395 kg
MOUNTING MODE
Not rack-mountable
TWO POST MOUNTABLE
0
USB COMPATIBLE
No
WIDTH
141.2 cm
Input
NETWORK FREQUENCY
45…65 Hz
NUMBER OF INPUT CONNECTORS
1 hard wire 5-wire (3P + N + E)
INPUT VOLTAGE LIMITS
323…437 V adjustable 380 V
340…460 V adjustable 400 V
357…477 V adjustable 415 V
340…477 V
INPUTVOLT_OTHER
380 V
415 V
MAXIMUM INPUT CURRENT
122 A
SWITCHING CURRENT CAPACITY
160 A
MAX SHORT TIME WITHSTAND CURRENT
16 kA
INPUT HARMONIC DISTORTION
Less than 5 % for full load
INPUT PROTECTION TYPE
3-pole circuit breaker
INPUT VOLTAGE
400 V 3 phases
INRUSH CURRENT
200 A peak
LOAD POWER FACTOR
0.5 leading to 0.5 lagging
Output
RATED POWER IN W
72000 W
MAXIMUM CONFIGURABLE POWER IN W
72000 W
HARMONIC DISTORTION
Less than 5 %
OUTPUT FREQUENCY
50/60 Hz +/- 1 Hz sync to mains
50/60 Hz +/- 1 Hz unsynchronised
OUTPUTVOLT_OTHER
380 V
415 V
CREST FACTOR
3 : 1
UPS TYPE
Double conversion online
OUTPUT CONNECTOR TYPE
Hard wire 5-wire (3P + N + E) 1
OUTPUT VOLTAGE TOLERANCE
+/- 2% static and 100% load step
OUTPUT HARMONIC DISTORTION
< 3% linear load and < 5% non-linear load
OUTPUT OVERLOAD OPERATION
10 minutes at 125% and 30 seconds at 150%
REQUIRED OUTPUT CURRENT PROTECTION
160 A
BYPASS TYPE
Built-in static bypass
CURVE EQUATION
Efficiency
CURVE FIXED LOSS
0.0124
CURVE LOAD MAXIMUM
100 %
CURVE LOAD MINIMUM
2 %
CURVE PROPORTIONAL LOSS
0.0296
CURVE SQUARE LOSS
0.0243
CURVE X-AXIS MAXIMUM
100 %
CURVE TEST COND ID
Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced PF = 0.8 output.
CURVE X-AXIS MINIMUM
0 %
CURVE X-AXIS TITLE
Load
CURVE X-AXIS UNITS
Percentage
CURVE Y-AXIS MAXIMUM
100 %
CURVE Y-AXIS MINIMUM
50 %
CURVE Y-AXIS TITLE
Efficiency
CURVE Y-AXIS UNITS
Percentage
GRAPH DISPLAY
0
OUTPUT VOLTAGE
400 V 3 phases
MAXIMUM CONFIGURABLE POWER IN VA
80000 VA
RATED POWER IN VA
80000 VA
Conformance
PRODUCT CERTIFICATIONS
CE
EAC
STANDARDS
EN/IEC 62040-1
EN/IEC 62040-2
EN/IEC 62040-3
ISTA 2B
Environmental
AMBIENT AIR TEMPERATURE FOR OPERATION
0…40 °C
RELATIVE HUMIDITY
0…95 % non-condensing
OPERATING ALTITUDE
0…3000 ft
AMBIENT AIR TEMPERATURE FOR STORAGE
-15…40 °C
STORAGE RELATIVE HUMIDITY
0…95 % Non-condensing
STORAGE ALTITUDE
0.00…4572.00 m
ACOUSTIC LEVEL
65 dBA
SHOW NOTE OP TEMPERATURE
No
IP DEGREE OF PROTECTION
IP20
Batteries & Runtime
BATTERY TYPE
Lead-acid battery
NUMBER OF BATTERY FILLED SLOTS
0
NUMBER OF BATTERY FREE SLOTS
0
ADDITIONAL INFORMATION
KW/kVA = 0.9 PF with ambient temp up to 25°C. kW/kVA = 0.8 PF with ambient temp above 25°C
LIQUID VALUE
0
BATTERY VOLTAGE
+/- 192 V (split battery referenced to neutral)
DISCHARGE BATTERY VOLTAGE
+/- 154 V
BATTERY CURVE
B
BATTERY POWER IN VAH
0 VAh runtime
BATTERY LIFE
3…5 year(s)
EXTENDED RUNTIME
0
Communications & Management
PREINSTALLED DEVICE
Network management card
CONTROL PANEL
Multifunction LCD status and control console
EMERGENCY POWER OFF
Yes
Packing Units
PACKAGE 1 WEIGHT
1435 kg
PACKAGE 1 HEIGHT
197.8 cm
PACKAGE 1 WIDTH
164.9 cm
PACKAGE 1 LENGTH
112 cm
Offer Sustainability
EU ROHS DIRECTIVE
Under investigation
MERCURY-FREE
Yes
ROHS EXEMPTION INFORMATION
Yes
ENVIRONMENTAL DISCLOSURE
Product Environmental Profile
CIRCULARITY PROFILE
End of Life Information
OPTIMIZED ENERGY EFFICIENCY
Energy-efficient product
Reviews (0)
Ratings

0.0

0 Product Ratings
5
0
4
0
3
0
2
0
1
0

Review this product

Share your thoughts with other customers

Write a review

Reviews

There are no reviews yet.