Mecer ME-2000-WPTU 2KVA Online Smart UPS
Mecer ME-2000-WPTU 2KVA Online Smart UPS from the leading mecer smart UPS dealer in Nairobi Kenya, buy online ME-2000-WPTU 2KVA Online Smart UPS .
Mecer 2000VA On-Line Tower UPS (ME-2000-WPTU) – Capacity: 2000VA / 1600W, Battery Type: 12V/9Ah, Frequency Range: 40Hz ~ 70 Hz, Includes AVR, Monitoring Software, Built-in Surge Protection, Black Colour Mecer ME-2000-WPTU 2KVA Online Smart UPS can charge up to 90% in battery capacity within a 4 hour period.
This UPS is generator compatible and the Waveform is Pure Sinewave. Mecer 2000VA On-Line Tower UPS (ME-2000-WPTU) has a wide input voltage range and an available converter mode.
Mecer ME-2000-WPTU 2KVA Online Smart UPS specifications
Phase Single phase with ground
Capacity 2000 VA / 1600 W
Input Voltage Range Low Line Transfer 160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5% (Ambient Temp. < 35°C) (based on load percentage 100% – 80% / 80% – 70% / 70-60 % / 60% – 0)
Low Line Comeback 175 VAC / 155 VAC / 135 VAC / 125 VAC ± 5% (Ambient Temp. <35°C) (based on load percentage 100% – 80% / 80% – 70% / 70 60% / 60% – 0)
High Line Transfer 300 VAC ± 5%
High Line Comeback 290 VAC ± 5%
Frequency Range 40HZ ~ 70 HZ
Power Factor ? 0.99 @ nominal voltage
Output Output Voltage 200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronised Range) 47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
Current Crest Ratio 3:1 Harmonic Distortion ? 3 % THD (Linear Load), ? 6 % THD (non-linear load)
Transfer Time AC Mode to Batt. Mode Zero
Inverter to Bypass 4 ms (Typical)
Waveform (Batt. Mode) Pure Sinewave
Efficiency AC Mode 89%
Battery Mode 87%
Battery Battery Type 12 V 9 Ah
Numbers 4 Typical Recharge Time 4 hours to recover to 90% capacity
Charging Current (max.) 1.0 A
Charging Voltage 54.7 VDC ± 1%
Indicators LCD Panel UPS status, Load level, Battery level, Input/output Voltage, Discharge timer and Fault Conditions
Alarm Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
Physical Dimension, D x W x H (mm) 397 x 145 x 220
Net Weight (kgs) 17
Environment Humidity 20-90 % RH @ 0-40°C (non-condensing)
Noise Level Less than 50dB @ 1 Meter
Management Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix and Mac
Optional SNMP Power management from SNMP manager and web browser