Description

Smart Pro 230V 2.2kVA 1.6kW Line Interactive UPS Tower Network Card Options USB DB9 Serial

 prevents data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges. Large internal batteries offer 19 minutes half load runtime and 7 minutes at full load. Maintains regulated 230V nominal output without using battery power during brownouts and over voltages from 151 to 282V. 2200VA power handling capability offers compatibility with a variety of networking, telecom and other sensitive electronic applications. Includes a total of 9 outlets with 3 load banks (2 outlets each) that are individually switchable via software interface to reboot select equipment on demand or shed less significant loads to extend battery runtime for more critical equipment. Supports simultaneous remote monitoring of UPS and site power conditions via built-in USB and DB9 monitoring ports. Power Alert UPS monitoring software is available via free download. Built-in accessory slot supports Network Management Card options. Emergency Power Off (EPO) interface offers option for instantaneous power-off of UPS and connected equipment in the case of fire or emergency. Multi-function audible alarms and set of 5 front panel LEDs offer at-a-glance notification of UPS and line power status. Network-grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise. Attractive gray color scheme.

Features

  • SMARTINT2200VS line interactive UPS offers protection from blackouts, brownouts, over voltages and surges
  • 2200VA / 1600 watt capacity
  • Internal batteries support a half load of 1100VA for 19 minutes and a full load of 2200VA for 7 minutes
  • Intelligent battery management system extends battery life
  • Maintains regulated 230V nominal output during brownouts and over voltages from 151 to 282V
  • Includes 9 UPS supported outlets with 3 individually controllable load banks that can be powered off and back on again via software interface
  • IEC320-C20 input connection accepts a variety of detachable cord sets to match country or site-specific wall receptacles
  • Power Alert UPS monitoring and unattended shutdown software included
  • USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite’s Power Alert software, available via FREE download from www.tripplite.com/poweralert
  • Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for immediate reboot of connected devices
  • Supports Tripp Lite’s Watch Dog software application (requires optional WATCHDOGSW)
  • Built-in accessory slot supports Network Management Card options; Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX and SNMPWEBCARD
  • Emergency Power Off (EPO) interface with cable
  • Multi-function audible alarms and set of 5 front panel LEDs
  • Network-grade AC surge suppression
  • Attractive gray color scheme
  • Optional PDUBHV20 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment

Specifications

OVERVIEW
UPC Code 037332120304
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 11.3A
Nominal Input Voltage(s) Supported 230V AC
UPS Input Connection Type C20 inlet
UPS Input Connection Description IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 2200
Output kVA Capacity (kVA) 2.20
Output Watt Capacity (Watts) 1600
Output kW Capacity (kW) 1.60
Power Factor 0.7
Nominal Voltage Details 230v inverter nominal output voltage
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) -19% +8%
Output Voltage Regulation (Battery Mode) +/- 5%
Included Output Power Cables Includes 3 C13 to C14 output power cables
Load Management Receptacles Three switchable two-outlet C13 load banks
Output Circuit Breakers 10A (x2) – each breaker protects 4 C13 outlets each, C19 is unbreakered
Hot-Swap PDU options PDUBHV20 (2U / 6 C13, 2 C19 outlets)
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Output Receptacles (8) C13; (1) C19
Individually Controllable Load Banks Yes
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 7 min. (1600w)
Half Load Runtime (min.) 19 min. (800w)
Expandable Runtime No
DC System Voltage (VDC) 48
Battery Recharge Rate (Included Batteries) Less than 4 hours from 10% to 90% (typical, full load discharge)
Battery Access Battery access door
Internal UPS Replacement Battery Cartridge  RBC54
Battery Replacement Description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V
Overvoltage Correction Input voltages between 245 and 282 are reduced by 12%
Under voltage Correction Input voltages between 177 and 199 are boosted by 14%
Severe Under voltage Correction Input voltages between 151 and 176 are boosted by 30%
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 480
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Cooling Method Fan
Installation Form Factors Supported with Included Accessories Tower
Primary Form Factor Tower
Primary UPS Depth (mm) 305
Primary UPS Height (mm) 361
Primary UPS Width (mm) 234
Shipping Dimensions (hwd / cm) 49.02 x 38.61 x 40.39
Shipping Weight (kg) 27.49
UPS Housing Material Polycarbonate
UPS Power Module Dimensions (hwd, cm) 36.07 x 23.37 x 30.48
UPS Power Module Weight (kg) 24.49
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode Efficiency Rating (100% Load) 94%
Audible Noise Audible Noise < 47dBA At Front Side 1 Meter
COMMUNICATIONS
Network Management Cards  SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total)
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable 2 USB and 2 DB9 cables included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Communications Interface Contact closure; DB9 Serial; Slot for SNMP/Web interface; USB
LINE / BATTERY TRANSFER
Transfer Time 2-4 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 151
High Voltage Transfer to Battery Power (Setpoint) 282
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Hot swappable batteries; Auto Probe Monitoring and Reboot (requires WEBCARDLX)
STANDARDS & COMPLIANCE
UPS Certifications CE; Meets FCC Part 15 Category A (EMI)
Certification Details CE 62040
WARRANTY
Product Warranty Period (International) 2-year limited warranty

best products outcome