SMART5000XFMRXL – Tripp Lite Smart Pro 5000VA Specifications:

 

Input:

Rated input current (Maximum Load) 24A
Nominal Input Voltage(s) Supported 208V AC
UPS Input Connection Type
NEMA L6-30P
Input Circuit Breakers 20A
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.1
Recommended Electrical Service 30A 208V
Input Phase Single-Phase

Output:

Output Volt Amp Capacity (VA) 5000
Output kVA Capacity (kVA) 5
Output Watt Capacity (Watts) 3750
Output kW Capacity (kW) 3.75
Power Factor 0.75
Nominal Voltage Details 208/120V nominal output in battery mode
Frequency Compatibility 60 Hz
Output Voltage Regulation (Line Mode) 208 & 120V (+/- 10%)
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 5%
Load Management Receptacles Eight switchable single-outlet 5-15/20R load banks
Output Circuit Breakers 20A double pole breaker supports L6-20R outlets, 20A branch rated breaker (x2) supports 4 5-15/20R outlets each, L6-30R outlet is unbreakered
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 110V; 115V; 120V; 208V
Output Receptacles
(8) NEMA 5-15/20R
 (2) NEMA L6-20R
(1) NEMA L6-30R
Individually Controllable Load Banks Yes


Battery:

Full Load Runtime (min.) 8.5 min. (3750w)
Half Load Runtime (min.) 20 min. (1875w)
Expandable Battery Runtime Extended runtime supported via optional external battery packs
External Battery Pack Compatibility BP48V27-2US  (multi-pack compatible);  BP48V60RT-3U  (multi-pack compatible)
DC System Voltage (VDC) 48
Battery Recharge Rate (Included Batteries) 6.8 hours from 10% to 90% (typical, full load discharge)
Internal UPS Replacement Battery Cartridge RBC94-3U  (quantity 3)
Battery Access Front panel battery access door
Battery Replacement Description Hot-swappable, user replaceable batteries
Expandable Runtime Yes

Voltage Regulation:

Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 167 to 260
Overvoltage Correction Input voltages between 228 and 260 are reduced by 12%
Undervoltage Correction Input voltages between 167 and 194 are boosted by 12%

User Interface, Alerts & Controls:

Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low battery status
Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status

Surge / Noise Suppression:

UPS AC Suppression Joule Rating 1020
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes


Physical:

Cooling Method Fan
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )
Minimum Required Rack Depth with External Battery Pack (cm) 81
Minimum Required Rack Depth with External Battery Pack (in.) 32
Minimum Required Rack Depth without External Battery Pack (cm) 76
Minimum Required Rack Depth without External Battery Pack (in.) 30
Primary Form Factor Rackmount
Primary UPS Depth (mm) 635
Primary UPS Height (mm) 132
Primary UPS Width (mm) 445
Rack Height 3U
Shipping Dimensions (hwd / cm) 30.48 x 58.42 x 83.82
Shipping Dimensions (hwd / in.) 12.00 x 23.00 x 33.00
Shipping Weight (kg) 83.91
Shipping Weight (lbs.) 185.00
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, cm) 13.21 x 44.45 x 63.50
UPS Power Module Dimensions (hwd, in.) 5.2 x 17.5 x 25
UPS Power Module Weight (kg) 65.00
UPS Power Module Weight (lbs.) 143.3


Environmental:

Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 5 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 366
AC Mode Efficiency Rating (100% Load) 97%
Audible Noise 45 dBA maximum, front side 1m


Communications:

Network Management Cards SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
Power Alert Software For local monitoring via the UPS’s built-in communication ports, download Power Alert Local software
Communications Cable USB
Watch Dog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB