2 Zone Fire Alarm Control Panel AW-CFP2166-2 Asenware
KSh20,000.00Original price was: KSh20,000.00.KSh17,000.00Current price is: KSh17,000.00. ( Ex VAT )
-15%
2 Zone Fire Alarm Control Panel AW-CFP2166-2 Asenware
2 Zone Fire Alarm Control Panel AW-CFP2166-2 Asenware series conventional fire alarm panel is designed based on EN54 part 2?4 standard. And it is the central part of conventional fire alarm system, 2 Zone Fire Alarm Control Panel designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.
The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications. Asenware 2 Zone Fire Alarm Control Panel has 2 level control mode by a lock, fire and fault signal output, optical GSM module for fire alarm by SMS, 2 general sounders output, battery low protection function,Ā silence button to stop buzzer and sounders, each zone can be disabled by a button, battery not included.
2 Zone Fire Alarm Control Panel is a typical one zone fire alarm control panel that is designed based on EN54 part 2 & 4 standard. It is the heart of the fire automatic alarm system, which can realize centralized control, 2 Zone Fire Alarm Control Panel can supply power to the detectors, manual call point, bell and more. One zone of the panel can match with 20 pieces fire alarm system accessories.
Asenware 2 Zone Fire Alarm Control PanelĀ fire alarm system wire drawing is for reference. Fire alarm control panels are designed to fulfill the requirements of EN54 parts 2 & 4 as well as being easy to install, operate and maintain. Being of modular construction
Asenware 2 Zone Fire Alarm Control Panel specifications
ITEM
1Zone panel
2Zone panel
4-16 Zone panel
4-32 Zone panel
Photo
Model No.
AW-CFP2166-01
AW-CFP2166-02
AW-CFP2166-04-16
AW-CFP2166-04-32
Power specification
Mains supply voltage
110VAC or 240VAC
Internal power supply
27.2VDC
Total output current limited
500mA @ 240VAC
500mA @ 240VAC
3A @ 240VAC
3A @ 240VAC
Main supply monitor for fault
Yes
Battery protection for low voltage
Yes
Batteries (default configuration)
12V2AH*2
Detector circuit specification
Number of circuit
1
2
4-16
4-32
Line fault monitor for open circuit
Yes
Line fault monitor for short circuit
Yes
Line fault monitor for detector removal
Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value
470 to 680 ? , 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone
20 (based on a total detector current of 2mA, each detector consuming 100? A). Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
2 Zone Fire Alarm Control Panel AW-CFP2166-2 Asenware
AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. 2. It is modularized design, the panel can extend from 1 zone to 32 zones easily. 3. It has 2 level control mode by a lock 4. It has 24VDC and 5VDC power supply output. 5. It has FIRE and FAULT signal output. 6. It has 2 general sounders output. 7. Each zone has 1 circuit detectors input. 8.
Each zone can be disable by a button. 9. It has RESET button to reset the panel. 10. It has SILENCE button to stop BUZZER and SOUNDERS. 11. It has EVACUATE button to start a manual fire alarm immediately. 12. It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.